BTU Calculator
Enter your room dimensions and conditions to get the cooling capacity you need. Results are shown in BTU/h, tons, and kW, with the exact adjustments applied.
Estimates assume a standard wood-frame room. Add 10–20% for uninsulated walls, large west-facing windows, or rooms above a garage. For a final equipment decision, ask for a Manual J load calculation.
How this BTU calculator works
The base load comes from published room-sizing charts rather than a single flat multiplier, so small bedrooms and large open-plan spaces both land in a realistic range:
- Up to 300 sq ft: 28 BTU per square foot
- Above 300 sq ft: 20 BTU per square foot on the area beyond 300
- Minimum: 5,000 BTU/h, even for very small rooms
That base load is then adjusted:
- Ceiling height: multiply by ceiling height ÷ 8 ft
- Climate: −10% cold, +15% hot and humid
- Sun exposure: −10% shaded, +10% very sunny
- Occupants: +600 BTU/h for each person beyond two
- Kitchen or heat-producing appliances: +4,000 BTU/h
The recommended unit size shown is ±10% of the calculated load, rounded to 500 BTU/h, which matches how equipment is actually sold.
BTU sizing chart by room size
| Room size | Cooling capacity | Tons |
|---|---|---|
| 100–150 sq ft | 5,000–6,000 BTU/h | 0.4–0.5 |
| 150–250 sq ft | 6,000–8,000 BTU/h | 0.5–0.7 |
| 250–350 sq ft | 8,000–10,000 BTU/h | 0.7–0.8 |
| 350–450 sq ft | 10,000–12,000 BTU/h | 0.8–1.0 |
| 450–550 sq ft | 12,000–14,000 BTU/h | 1.0–1.2 |
| 550–700 sq ft | 14,000–18,000 BTU/h | 1.2–1.5 |
| 700–1,000 sq ft | 18,000–24,000 BTU/h | 1.5–2.0 |
Charts like this assume an 8 ft ceiling, average sun, and two occupants. Use the calculator above when any of those assumptions do not hold.
Why other BTU calculators give different numbers
You may see a different number on another site for the same room — sometimes a much higher one. That is not a bug; different calculators answer slightly different questions.
- This calculator uses the ENERGY STAR room sizing chart and the common 20 BTU per square foot rule, with explicit adjustments for ceiling height, climate, sun exposure, and occupants. For a 500 sq ft room that lands around 12,000–13,000 BTU/h — the range most HVAC contractors and major brands use to avoid oversizing.
- Some other calculators model heat gain directly: they estimate U-value × surface area × temperature difference, and bake in more aggressive assumptions about insulation, windows, and climate. That can push the number to 18,000–22,000 BTU/h for the same 500 sq ft room.
Neither approach is wrong, but sizing up to the higher number is usually the more expensive choice. An oversized air conditioner cools the room too fast, cycles on and off repeatedly, removes humidity poorly, and uses more electricity over its lifetime. If you want a conservative margin, add 10–20% to the number shown here rather than starting from a high-side estimate.
For a final equipment decision, a contractor's Manual J load calculation is the most accurate. It accounts for insulation values, window ratings, ductwork, and local weather in a way no online calculator can.
Frequently asked questions
How many BTUs do I need per square foot?
The common rule is 20 BTU per square foot for rooms over 300 sq ft, and a steeper 28 BTU per square foot for smaller rooms, where heat loss through walls, doors, and equipment matters more per square foot. Both are adjusted for ceiling height, climate, sun exposure, and occupants.
What is a BTU?
A British Thermal Unit is the energy needed to raise one pound of water by 1°F. Air conditioners are rated in BTU per hour (BTU/h), which is how much heat the unit removes each hour.
How many BTU is one ton of air conditioning?
One ton of cooling equals 12,000 BTU/h. So a 24,000 BTU/h unit is a 2-ton unit. Divide BTUs by 12,000 to convert.
Does ceiling height change the BTU requirement?
Yes. Cooling load scales with room volume, not floor area. The calculator multiplies the base load by ceiling height ÷ 8, so a 12 ft ceiling adds 50% to the base load.
Can I install an AC that is larger than the calculation?
It is safer to avoid oversizing. An oversized unit cools the air quickly but shuts off before removing humidity, leaving the room cold and clammy, and it wears out faster from short cycling. Stay within about 10% of the calculated load.
Is this BTU calculator accurate enough to buy from?
It is a solid planning estimate based on published sizing charts. For a purchase you intend to live with for years, have a contractor run a Manual J load calculation that accounts for insulation, window ratings, ductwork, and air infiltration.
BTU requirements by room size
Pre-filled calculators for common room dimensions: